Rack PDU, Basic, Zero U, 5.7kW, 208V, (36)C13 & (6)C19
-Includes: Installation guide, Rack Mounting brackets, Toolless Mounting Kit. -Multi-branch power input. -Toolless mounting capability. -Vertical mounting capability. More Info
208V, 47-63Hz, 1.83m, 50A, 55x88x927mm, 7.26kg, Black
Marketing Features- Low Cost Power Distribution Provides a number of outlets to bring power to rack equipment at an affordable price. - Rack-Mountable Includes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment. - Single input power source Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections. - Wide range of input and output... More Info
2U, 30A, 208V, 12x C13s, 4x C19, NEMA L6-30P, 444 x 112 x 88 mm, 3360 g
AvailabilityAlarm Thresholds Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability)Local Current Monitoring Display The aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum... More Info
208V, 50/60Hz, 35A, 12.5kVA, 0U, 56 x 89 x 1778mm, 8.08kg, Black
Local Current Monitoring DisplayThe aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.Alarm ThresholdsDefine alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.Power DelaysAllows users to configure the sequence in which power is turned on or off... More Info
Rack PDU Blue label kit (Quantity 10 units)
Unique colors, input cord plugs and outlet configurations done simply and delivered to specification.Single input power source Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.Power Delays Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also... More Info
Rack PDU Red label kit (Quantity 10 units)
Unique colors, input cord plugs and outlet configurations done simply and delivered to specification.Single input power source Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.Power Delays Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also... More Info
Rack PDU 2G, Switched Plus, ZeroU, 30A, 200/208V, (21) C13 & (3) C19
Network Management Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.Remote Individual Outlet Control Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up... More Info
Rack PDU 2G, Metered, ZeroU, 17.2kW, 208V, (6) C13 & (12) C19
APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC... More Info
Basic Rack PDU , Input: 120V , Input Connections: NEMA L5-30P , Cord Length:...
19 inch Rack-Mountable Supplies redundant AC power to connected equipment. Two AC lines power the unit and if the primary AC power fails, the unit will automatically switch to the alternate power source.Resettable circuit breakers Enables a quick recovery from overload events. Vertical mounting capability. Horizontal mounting capability. More Info
Step-Down Transformer RM 2U 208V IN 120V OUT w/Hardwire Input/Output
Transformer for Step-down or Step-up or Isolation Step down transformer placed upstream of the UPS to avoid inrush current and saturation eliminating need to oversize transformerMeets UL Requirements More Info