APC APDU10450ME
  • APC APDU10450ME
  • APC APDU10450ME
  • APC APDU10450ME
  • APC APDU10450ME
  • APC APDU10450ME
  • APC APDU10450ME
  • APC APDU10450ME
  • APC APDU10450ME
  • APC APDU10450ME
  • APC APDU10450ME
  • APC APDU10450ME
  • APC APDU10450ME
  • APC APDU10450ME
APC NetShelter Rack PDU Advanced, Metered, 34.6kW, 3PH, 415V, 60A, 560P6, 42 Outlet
APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. PDU level power metering via remote access and local display for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 42 outlets in a 2.2" wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. For data center deployments across multiple regions, these PDUs are both UL and CE rated providing one PDU that can be used globally to simplify and standardize deployment.
AC input frequency50 - 60 Hz
AC outlet typesC13 coupler,C15 coupler,C19 coupler,C21 coupler
AC outlets quantity48 AC outlet(s)
CertificationCSA C22.2 No 62368-1, FCC part 15 subpart B, UL 62368-1
Depth75 mm
DisplayLCD
Height1826 mm
Load capacity34600 VA
Maximum current60 A
Maximum input current per phase60 A
Maximum total current draw per phase48 A
Mountingvertical
Nominal input voltage415 V
Nominal output voltage240 V
Non-operating altitude0 - 15240 m
On/off switchN
Operating altitude0 - 3048 m
Operating relative humidity (H-H)5 - 95 %
Operating temperature (T-T)-5 - 60 °C
Output voltage240 V
Package height1980 mm
Package weight14700 g
Package width262 mm
PDU typesSwitched
Power plugIEC 60309
Rack capacity0U
Storage relative humidity (H-H)5 - 95 %
Storage temperature (T-T)-25 - 65 °C
TypeSingle-phase
Weight11700 g
Width56 mm

Similar products

  • APC Basic Rack PDU AP7526
    APC Basic Rack PDU AP7526
  • APC Basic Rack PDU
    APC Basic Rack PDU
  • APC Basic Rack PDU
    APC Basic Rack PDU
  • APC Rack PDU. Basic. Zero u. 32a. 230v. (20)c13 & (4)c19
    APC Rack PDU. Basic. Zero u. 32a. 230v....
  • APC Basic Rack PDU
    APC Basic Rack PDU

APC APDU10450ME

50/60 Hz, 200 - 240, 346 - 415VAC, Load Capacity 34600VA

apdu10450me

Out of Stock

£2,861.58
£2,384.65 Ex VAT.

Require project pricing? - request a quoteNeed a trade account? - send us your details Are you a public sector organistion? - open a credit account